|
Agilent technologies
cy3 streptavidin solution Cy3 Streptavidin Solution, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cy3 streptavidin solution/product/Agilent technologies Average 99 stars, based on 1 article reviews
cy3 streptavidin solution - by Bioz Stars,
2026-06
99/100 stars
|
Buy from Supplier |
|
Sartorius AG
surescan dna microarray scanner ![]() Surescan Dna Microarray Scanner, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/surescan dna microarray scanner/product/Sartorius AG Average 95 stars, based on 1 article reviews
surescan dna microarray scanner - by Bioz Stars,
2026-06
95/100 stars
|
Buy from Supplier |
|
LI-COR
microarray scanners ![]() Microarray Scanners, supplied by LI-COR, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microarray scanners/product/LI-COR Average 99 stars, based on 1 article reviews
microarray scanners - by Bioz Stars,
2026-06
99/100 stars
|
Buy from Supplier |
|
JPT Peptide Technologies GmbH
peptide microarray ![]() Peptide Microarray, supplied by JPT Peptide Technologies GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/peptide microarray/product/JPT Peptide Technologies GmbH Average 90 stars, based on 1 article reviews
peptide microarray - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
OakLabs Inc
arrayxs-068300 ![]() Arrayxs 068300, supplied by OakLabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/arrayxs-068300/product/OakLabs Inc Average 90 stars, based on 1 article reviews
arrayxs-068300 - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
OakLabs Inc
arrayxs-068300 with wormbase ws241 genome build ![]() Arrayxs 068300 With Wormbase Ws241 Genome Build, supplied by OakLabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/arrayxs-068300 with wormbase ws241 genome build/product/OakLabs Inc Average 90 stars, based on 1 article reviews
arrayxs-068300 with wormbase ws241 genome build - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Innopsys Inc
innoscan ![]() Innoscan, supplied by Innopsys Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/innoscan/product/Innopsys Inc Average 86 stars, based on 1 article reviews
innoscan - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
BioMicro Systems Inc
maui wash system biomicro systems ![]() Maui Wash System Biomicro Systems, supplied by BioMicro Systems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/maui wash system biomicro systems/product/BioMicro Systems Inc Average 90 stars, based on 1 article reviews
maui wash system biomicro systems - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Illumina Inc
exemplary microarray imaging apparatus ![]() Exemplary Microarray Imaging Apparatus, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/exemplary microarray imaging apparatus/product/Illumina Inc Average 97 stars, based on 1 article reviews
exemplary microarray imaging apparatus - by Bioz Stars,
2026-06
97/100 stars
|
Buy from Supplier |
|
BioMicro Systems Inc
maui wash system ![]() Maui Wash System, supplied by BioMicro Systems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/maui wash system/product/BioMicro Systems Inc Average 90 stars, based on 1 article reviews
maui wash system - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Oxford Gene Technology
cytosure tm constitutional v3 + loh arrays reagent kit 4 × 180 k format ![]() Cytosure Tm Constitutional V3 + Loh Arrays Reagent Kit 4 × 180 K Format, supplied by Oxford Gene Technology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/cytosure tm constitutional v3 + loh arrays reagent kit 4 × 180 k format/product/Oxford Gene Technology Average 90 stars, based on 1 article reviews
cytosure tm constitutional v3 + loh arrays reagent kit 4 × 180 k format - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Promega
genomic dna ![]() Genomic Dna, supplied by Promega, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/genomic dna/product/Promega Average 90 stars, based on 1 article reviews
genomic dna - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Bio-protocol
Article Title: Detection of Pathogens and Ampicillin-resistance Genes Using Multiplex Padlock Probes
doi: 10.21769/BioProtoc.2504
Figure Lengend Snippet: . The 3’ and the 5’ target recognition arms bind to the multiplex PCR products of the β-lactamase genes. During the binding process, the padlock probes are circularized and subsequently ligated. The maximum distance of the padlock probe binding region to the 3’ or 5’-ends of the PCR product should not exceed 200 base pairs. Since the padlock probes gets concatenated with the PCR product upon the ligation reaction, longer distances cause an inhibition of subsequent RCAs. The C2CA sequence is needed for the circle-to-circle amplification and comprises an AluI restriction site for monomerization of the amplification products. The barcode sequence is derived from the 16S rRNA gene. This allowed us to halve the number of microarray probes because the C2CA products and 16S rRNA gene PCR products are detected on the same microarray probe but in different fluorescence channels.
Article Snippet: Pipettes ( e.g ., Sartorius, catalog numbers: 728020, 728050, 728060 and 728070) Microbiological incubator shaker ( e.g ., IKA, model: KS 4000 i control) Tabletop centrifuge for 1.5 ml tubes ( e.g ., Eppendorf, model: 5424) Roche MagNA Lyser Instrument (Basel, Switzerland) Thermomixer comfort (Eppendorf, Hamburg, Germany) Epoch Microplate spectrophotometer (Biotek, Winooski, VT, USA) Biosan DNA/RNA UV-cleaner box (Warren, MI, USA) (recommended, see Note 4) Thermal cycler ( e.g ., Thermo Fisher Scientific, Applied Biosystems, model: GeneAmp TM PCR System 2700) (Paisley, UK) Heraeus Megafuge 40R with a TX-750 rotor (Thermo Fisher Scientific, Thermo Scientific TM , model: Heraeus TM Megafuge TM 40R, catalog number: 75004518; TX-750 rotor: Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003180) and inserts for plates (Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003617) and Falcon tubes (Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003608) Slide humidity incubation box ( e.g ., LabScientific, catalog number: HIC-3) GeneMachines Omnigrid 100 contact arrayer (Madison, WI, USA) International Microarray Pin Stealth 3 SMP3 (Telechem, catalog number: SMP3) Agilent
Techniques: Multiplex Assay, Binding Assay, Ligation, Inhibition, Sequencing, Amplification, Derivative Assay, Microarray, Fluorescence
Journal: Bio-protocol
Article Title: Detection of Pathogens and Ampicillin-resistance Genes Using Multiplex Padlock Probes
doi: 10.21769/BioProtoc.2504
Figure Lengend Snippet: For the species identification, the 16S rRNA gene is amplified using universal 16S primers (A1). Subsequently, the PCR products are labeled using a linear PCR and Cy5-modified cytosines (A2). In parallel, β-lactamase genes are pre-amplified in a 33-plex PCR (B1). Then, the padlock probes are hybridized (B2) and ligated (B3) using the β-lactamase PCR products as template and amplified in a first rolling circle amplification (RCA) (B4). The RCA products comprise a C2CA sequence and corresponding 16S rRNA barcode sequences. In a next reaction, the RCA products are monomerized (B5) using a restriction enzyme and circularized (B6) to serve as a new template for a second RCA (B7). These C2CA products are labelled in a linear PCR reaction using Atto532-modified cytosines (B8). Finally, the labelled amplification products from the 16S rRNA gene PCR and from the multiplex padlock assay are pooled together and hybridized to a microarray detecting the products at two different fluorescence wavelengths (C).
Article Snippet: Pipettes ( e.g ., Sartorius, catalog numbers: 728020, 728050, 728060 and 728070) Microbiological incubator shaker ( e.g ., IKA, model: KS 4000 i control) Tabletop centrifuge for 1.5 ml tubes ( e.g ., Eppendorf, model: 5424) Roche MagNA Lyser Instrument (Basel, Switzerland) Thermomixer comfort (Eppendorf, Hamburg, Germany) Epoch Microplate spectrophotometer (Biotek, Winooski, VT, USA) Biosan DNA/RNA UV-cleaner box (Warren, MI, USA) (recommended, see Note 4) Thermal cycler ( e.g ., Thermo Fisher Scientific, Applied Biosystems, model: GeneAmp TM PCR System 2700) (Paisley, UK) Heraeus Megafuge 40R with a TX-750 rotor (Thermo Fisher Scientific, Thermo Scientific TM , model: Heraeus TM Megafuge TM 40R, catalog number: 75004518; TX-750 rotor: Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003180) and inserts for plates (Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003617) and Falcon tubes (Thermo Fisher Scientific, Thermo Scientific TM , catalog number: 75003608) Slide humidity incubation box ( e.g ., LabScientific, catalog number: HIC-3) GeneMachines Omnigrid 100 contact arrayer (Madison, WI, USA) International Microarray Pin Stealth 3 SMP3 (Telechem, catalog number: SMP3) Agilent
Techniques: Amplification, Labeling, Modification, Sequencing, Multiplex Assay, Microarray, Fluorescence